Assumptions & modifiers
Quick mode: Baseline 40×ϕ (tension) / 30×ϕ (compression) with modifiers for bond, bar type, concrete class, and a conservative cover toggle. Minimums and 25 mm rounding applied.
Eurocode-2 mode: Computes l0 and lbd per EN 1992-1-1 §8.7 / §8.4 with UK-NA defaults; exposes α-coefficients via inputs and applies minimum rules.
Always verify with project specifications / your engineer.
⚠️ Important: This calculator is for indicative guidance only. Lap and anchorage lengths must always be confirmed by a qualified structural engineer and checked against project drawings, specifications, and applicable codes. Heaton Manufacturing accepts no liability for use of these values on site.
How to Use This Calculator
- Step 1: Enter your bar diameter and select whether the bar is in tension or compression.
- Step 2: Choose the concrete class and bond condition.
- Step 3: In Quick mode, the calculator will apply standard site rules of thumb (40×ϕ for tension, 30×ϕ for compression) with adjustments for bar type, cover, and bond.
- Step 4: In Eurocode-2 mode, you can add more detail: bar shape, cover to axis, confinement by transverse reinforcement, percentage of lapped bars, and National Annex parameters. The calculator then works through EN 1992-1-1 §8.4 and §8.7 to give both anchorage length (lbd) and lap length (l0).
- Step 5: Review the output shown on the right. In EC2 mode you can expand the “Worked Steps” panel to see the calculation process.
What the Calculator Does
- Gives you an indicative lap length for reinforcement bars based on the inputs you supply.
- In Quick mode it produces a fast, conservative estimate suitable for early checks, site conversations, or basic cutting schedules.
- In Eurocode-2 mode it gives a code-based calculation that accounts for bar shape, cover, confinement, and lap percentage, following EN 1992-1-1 (with UK NA defaults).
- Results are rounded to the nearest 25 mm to reflect practical site use.
Limitations and Assumptions
- Guidance only: This tool does not replace a structural engineer’s design. Always check project specifications and drawings.
- Eurocode scope: The EC2 option follows EN 1992-1-1:2004 with common UK National Annex defaults. Different NAs may set different values for γc, γs, or αct.
- Bar sizes: The EC2 tables and equations are valid for ribbed bars up to 32 mm. Adjustments apply automatically when larger diameters are entered.
- Simplifications: Confinement coefficients (α3, α4, α5) are treated as toggles rather than fully graded ranges.
- No detailing drawings: The calculator does not cover staggering layouts, transverse reinforcement detailing, or all cases of poor bond. Refer to EN 1992-1-1 Figures 8.1–8.9.
- Conservative rounding: Results are rounded and minimum rules enforced, so you may see slightly higher lengths than theoretical minimums.
Why Use It
- Lead directly into ordering bar lengths, cages, or reinforcement mesh.
- Quick answers without flipping through tables.
- Transparent Eurocode-2 breakdown if you need to justify lap lengths.